Description
Leica FlexLine TS07 1″ R500 Total Station
Original – Leica FlexLine TS07 1″ R500 Total Station
Includes:
Leica FlexLine TS07 1” R500 Reflectorless Total Station, AutoHeight module for automatic instrument height measurement, Electronic Guide Light EGL, WLAN, Bluetooth, RS232 interface, full numeric keyboard with 3.5” QVGA color touch screen
2x Leica GEB361 6-cell Lithium-Ion battery, Leica GKL311 battery charger
USB stick/SD card interface, 2GB Internal Flash Memory
Lens hood, Cleaning cloth
User manual
1 Year warranty
Container with protective cover
The new generation of Leica Flexline manual total station, Leica FlexLine TS10, Leica FlexLine TS07 and Leica Leica FlexLine TS03 Total Station. The TS07 is equipped with the Leica FlexField software, an intuitive, easy-to-use and familiar software. Guided workflows and easy to understand graphics and icons ensure a low learning curve when working in the field. The software makes the interpretation of measurement values or text no longer necessary and guarantees a faster and simple operation when you need it. With its pinpoint distance measurement system, you will be able to measure to both prisms and any surfaces. The TS07 offers the world’s first AutoHeight feature as an option. AutoHeight enables the instrument to automatically measure, read and set its instrument height. Prevent time consuming manual effort and eliminate critical errors during the instrument setup when this revolutionary feature uses a laser from the instrument to measure to the ground and automatically passes the measurement to the software.
Work Faster: Measure more points per day due to faster measurement and stakeout procedures (endless drives, trigger key, drives on both sides, pinpoint EDM and more), supported by our easy-to-use and familiar FlexField software. Speed up your learning curve onsite, take advantage of the great ergonomics and reliable measurements. Reduce errors and rework.
Use it trouble-free: Increase productivity and minimise downtime by relying on instruments that simple work and come with a global service and support network.
Choose products that are built to last: Even after years of use under harsh conditions (like mud, dust, blowing rain, extreme heat and cold), FlexLine still operates with the same high level of accuracy and reliability.
Control your investment: Instrument quality has been our standard for almost 200 years, which is why you can count on a lower investment over the entire instrument lifetime and do not have to worry about unexpected costs.
SPESIFICATION
Angular Measurement
Accuracy Hz and V Absolute, continuous, diametrical1 1” / 2” / 3” / 5” / 7”
Display resolution: 0.1’’ (0.1 mgon)
Quadruple axis compensation
Compensator setting accuracy2: 0.5” / 1”/ 1.5” / 2”
Compensator range: +/- 3.78’ (+/- 0.07gon)
Electronic level resolution: 2”
Circular level sensitivity: 6` / 2mm
Distance Measurement
Range
Prism (GPR1, GPH1P): 1.5m to 3.500m
Prism GPR1 (Long Range mode) > 10.000m
Non-Prism / Any surface
R500
R1000
Accuracy / Measurement time Single prism
Precise+ / Once: 1mm + 1.5ppm (typical 2.4s)
Precise&Fast / Once&Fast: 2mm + 1.5ppm (typical 2s)
Tracking / Continously: 3mm + 1.5ppm (typical < 0.15s)
Averaging: 1mm + 1.5ppm
Long Range mode / > 4km: 5mm + 2ppm (typical 2.5s)
Non-Prism / Any surface
0 m – 500m: 2mm + 2ppm (typical 3-6s)
> 500m: 4mm + 2ppm (typical 3-6s)
Laser dot size
At 30m: 7mm x 10mm
At 50m: 8mm x 20mm
At 100m: 16mm x 25mm
Telescope
Magnification: 30x
Resolving power: 3”
Focusing range: 1.55m / 5.08ft to infinity
Field of view: 1°30’ / 1.66gon / 2.7m at 100m
General
Display and keyboard 3.5“ (inch), 320 x 240 px QVGA, colour, touch, 28 keys5b
2nd keyboard
Key illumination
Operation
Endless drives for HZ & V
Trigger-Key: user definable with 2 functions
Power management Exchangeable Lithium-Ion battery
Operating time with GEB361 up to 30h
Operating time with GEB331 up to 15h
Battery charging time with
GKL341 charger for GEB361 / GEB331 3h 30min / 3h
GKL311 charger for GEB361 / GEB331 6h 30min / 3h 30min
Data storage
Internal memory: 2GB Flash
Memory card: SD card 1GB or 8GB
USB memory stick: 1GB
Processor
TI OMAP4430 1GHz Dual-core ARM® Cortex™ A9 MPCore™
Operating system – Windows EC7
Interfaces RS2327, USB device
Bluetooth®8, WLAN9
Mobile Data sidecover: LTE-Modem for internet access
Guide Light (EGL)
Working range: 5m to 150m
Position accuracy: 5cm at 100m
Wavelength red /orange: 617nm / 593nm
(R1000)
Laser plummet
(Laserclass 2) Accuracy
Plumb line deviation: 1.5mm at 1.5m instrument height
Diameter of laser point: 2.5mm at 1.5m instrument height
AutoHeight module for automatic instrument height measurement (Laserclass 2) Accuracy
Distance accuracy: 1.0mm @ 1m
Distance range: 0.7m to 2.7m
Weight 4.3 – 4.5kg
Environmental specifications Working temperature range: –20°C to +50°C
Arctic version: –35°C to +50°C
Dust / Water (IEC 60529) / Humidity: IP66 / 95%, non-condensing
Military Standard 810G, Method 506.5
Reviews
There are no reviews yet.