Miting Digital Analyzer

Free shipping worldwide. Orders over $200
Availability: In Stock

Original – Olympus Epoch 1000i

Original price was: $6,880.00.Current price is: $4,239.00.

Olympus Epoch 1000i-Ultrasonic Flaw Detector UT & Phased Array NDT In good working and cosmetic condition. Test Modes Pulse Echo

Other people want this. 15 people have this in their carts right now.
Category: Tag:

Description

Olympus Epoch 1000i

Original – Olympus Epoch 1000i

Olympus Panametrics Epoch 1000i Ultrasonic Flaw Detector UT & Phased Array NDT In good working and cosmetic condition. Tested and works. Recently used on a project. Ready for work.

General Overall Dimensions (W x H x D) 252 mm x 177 mm x 107 mm;
9.92 in. x 6.97 in. x 4.2 in.
Weight 3.67 kg (8.1 lb), including lithium-ion battery
Keypad English, International, Japanese, Chinese
Languages English, Spanish, French, German, Japanese, Chinese, Russian, Italian, Polish
Transducer Connections BNC or Number 1 LEMO®
Data Storage Onboard up to 10,000 IDs with waveform, standard 4 GB compact flash card (removable)
Battery Type Single lithium-ion rechargeable standard
Battery Life 8 hours (conventional UT mode); 7 hours (phased array mode)
Power Requirements AC Mains: 100 VAC to 120 VAC, 200 VAC to 240 VAC, 50 Hz to 60 Hz
Standby Mode Adjustable from 15 minutes to 120 minutes with 50% less battery consumption.
Display Type Full VGA (640 x 480 pixels) Transflective Color LCD, 60 Hz update rate
Display Dimensions (W x H, Diag.) 132.5 mm x 99.4 mm, 165.1 mm (5.2 in. x 3.9 in., 6.5 in.)

Inputs/Outputs USB Ports 1 USB Client, 3 USB Host ports
RS-232 Yes
Video Output VGA output standard
Analog Output 4 analog outputs, Selectable 1V/10V Full Scale, 4 mA max
Alarm Output 6 alarm outputs, 5V TTL, 10 mA
Trigger I/O Trigger input 5V TTL; trigger output, 5 V TTL, 10 mA
Encoder Inputs 2-axis encoder line (quadrature)

Environmental Ratings IP Rating Designed to meet requirements of IP66
Explosive Atmosphere Tested to MIL-STD-810F, Method 511.4, Procedure 1. Atmosphere defined per NFPA 70, Article 500 as Class I, Division 2, Group D.
Shock Tested IEC 600689-2-27, 60 g’s, 6 µsec Half-Sine, 18 Axes total
Vibration Tested Sine vibration, IEC 60068-2-6, 5 Hz to 150 Hz @ 0.03 in. or 2 g’s Displacement Amplitude, 20 sweep cycles
Operating Temperature -10° C to 50° C (-14° F to 122° F)
Battery Storage Temperature -20° C to 60° C (-4° F to 140° F)
Battery Recharge Temperature 0° C to 40° C (32° F to 104° F)

Epoch 1000i Phased Array Specifications Focal Laws 61
Physical Probe 64 elements
Virtual Probe 16 elements
Video Filtering Off, Low, High
Display Modes A-scan, S-scan, Linear scan, C-scan, A-scan plus image
Image Update Rate 60 Hz update for all A-scans; 20 Hz update for all images

EPOCH 1000i (PA mode) Pulser Type Tunable Square Wave
PRF Manually adjustable. Maximum 1520 Hz
Energy Settings 40 V or 80 V
Pulse Width Adjustable from 45 ns to 1,000 ns (0.5 MHz) with PerfectSquare™ Technology
Damping Not applicable
Pulser Delay 0 to 10 µs, 2.5 ns resolution

EPOCH 1000i (PA mode) Gain 0 to 80 dB
Maximum Input Signal 250 mVp-p per channel
Receiver Input Impedance 50 Ω ± 10%
Receiver Bandwidth 0.5 to 12.5 MHz @ -3 dB
Receiver Delay 0 to 10 µs, 2.5 ns resolution
Digital Filter Settings 6 filters
Rectification Full wave, positive half wave, negative half wave, RF
Reject 0 to 80% FSH with visual warning
Amplitude Measurement 0% to 110% full screen height with 0.25% resolution
Measurement Rate Equivalent to PRF in all models

Calibration

EPOCH 1000i (PA mode) Automated Calibration • Velocity, Zero Offset, Sensitivity
• Soundpath or Depth (Zero Offset)
Test Modes Pulse Echo
Units Millimeters, inches, or microseconds
Range 61 focal laws, 3.33 mm to 390.95 mm (0.131 in. to 15.373 in.) at 5900 m/s (0.2320 in./µs)
Velocity 635 m/s to 15,240 m/s (0.0250 in./µs to 0.6000 in./µs)
Zero Offset Automatic for all focal laws through calibration, or Manually adjustable from 0 to 100.00 µs (Global Delay Offset mode)
Display Delay 0 to max range
Refracted Angle 61 angular focal laws, 0.5°, 1.0°, 1.5°, or 2.0° increments Adjustable from -80° to +80°

Gates

EPOCH 1000i (PA mode) Measurement Gates Two fully independent gates for amplitude and time-of-flight measurements
Measurement Mode Soundpath, Depth
Interface Gate Not applicable
Gate Start Variable over entire displayed range
Gate Width Variable from gate start to end of displayed range
Gate Height Variable from 2% to 95% full screen height
Alarms • Positive and negative threshold (for selected focal law)
• Minimum depth (for selected focal law)
Reference Cursors 2 reference cursors for A-scans; 4 reference cursors for images

Measurements
EPOCH 1000i (PA mode) Displayed Measurement 6 locations available (manual or auto selection)
Gate 1 Thickness, soundpath, projection, depth, amplitude, time-of-flight, min/max. depth, min/max. amplitude
Gate 2 Same as Gate 1
IF Gate (optional) Not Applicable
Echo-to-Echo Standard. Choose between Gate2-1, Gate2-IF, Gate1-IF
Other Measurements Overshoot (dB) value for DGS/AVG, ERS(equivalent reflector size) for DGS/AVG, AWS D1.1/D1.5 rating (D), reject value
DAC/TVG Standard
DAC Points Up to 20 points, 40 dB dynamic
Special DAC Modes Not Applicable
TVG Table Up to 20 points, 40 dB dynamic
Curved Surface Correction Standard. Tube or bar OD correction for angle beam measurements

Included Accessories:

The EPOCH 1000 series offers various accessories to allow full functionality of available features.
EPXT-C-VGA-6 (U8779019): VGA output cable
EP4P/C-USB-6 (U8840084): USB client cable
EP1000-C-RS232-6 (U8779197): RS-232 communications cable
EP1000-C-26OUT-6 (U8779018): Hardware I/O cable (alarm outputs triggering)
EP1000-C-9OUT-6 (U8779017): Hardware I/O cable (analog output)
EP4/CH (U8140055): Chest harness
EPXT-EC-X: External battery charger
EPXT-BAT-L (U8760021): Extra battery (lithium-ion)
EP1000-TC-S (U8764078): Small Transport Case
EP1000-TC-L (U864079): Large Transport Case

Reviews

There are no reviews yet.

Be the first to review “Original – Olympus Epoch 1000i”

Your email address will not be published. Required fields are marked *

Olympus Epoch 1000i
You're viewing: Original – Olympus Epoch 1000i Original price was: $6,880.00.Current price is: $4,239.00.
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare