Description
Olympus OmniScan MX2 32:128 Ultrasonic Flaw Detector
Original – Olympus OmniScan MX2 32:128 Ultrasonic
The result of over 10 years of proven leadership in modular NDT test platforms, the OmniScan MX has been the most successful portable and modular phased array test instrument produced by Olympus to date, with thousands of units in use throughout the world.
Building on a Solid Basis
This second generation OmniScan MX2 increases testing efficiencies, ensuring superior manual and advanced AUT application performance with faster setups, test cycles, and reporting, in addition to universal compatibility with all phased array and ultrasound modules: past, present and future. Designed for NDT leaders, this high-end, scalable platform delivers true next-generation NDT performance.
The OmniScan MX2 offers a high acquisition rate and new powerful software features for efficient manual and automated inspection performance—all in a portable, modular instrument.
Faster Is Better!
Powerstart your day the right way with the OmniScan MX2. The OmniScan MX2 simplifies and speeds up the setup process with its intuitive Weld Overlay software feature, so you can start testing immediately. Featuring the industry-standard phased array user interface with faster-than-ever performance, a bigger and brighter 10.4 inch screen, new and unique intuitive touch-screen capabilities, and faster data transfer, enabling you to get to your next inspection quicker.
More than an Instrument —A Solution Provider
The OmniScan MX2 is an important part of your inspection solution, and can be combined with other critical components to form a complete inspection system. Olympus offers a complete product range that includes phased array probes, scanners, analysis software, and accessories, all of which are integrated and packaged into rapidly deployable, applicationspecific solutions for quick returns on your investment. In addition, Olympus offers a high-quality calibration and repair service worldwide, that is backed by a team of phased array application experts to ensure that you get the support you need.
Weld Inspection of Small-Diameter Pipes
When coupled with the COBRA manual scanner, the OmniScan flaw detector is capable of inspecting pipes ranging from 0.84 inch OD to 4.5 inch OD. With its very slim design, this manual scanner is able to inspect pipes in areas with limited access.
Pressure Vessel Weld Inspection
A complete inspection of pressure vessel welds can be performed manually, or in a single scan using an OmniScan and a scanner for a turnkey solution. Inspection results are available immediately, enabling you to detect problems with welding equipment and fix them right away
Composite Inspection
Olympus offers complete solutions for the inspection of carbon-fiberreinforced polymer structures. These solutions are based on the OmniScan flaw detector, the GLIDER™ scanner, and dedicated probes and wedges designed for CFRP flat panel and radius inspection.
Corrosion Mapping Inspection
The OmniScan PA system with the HydroFORM scanner is designed to offer the best inspection solution for the detection of wall-thickness reductions resulting from corrosion, abrasion, and erosion. For this application, phased array ultrasound technology offers superior inspection speed, data point density, and detection.
Specifications:
Overall dimensions (W x H x D) 325 mm x 235 mm x 130 mm (12.8 in. x 9.3 in. x 5.1 in.)
Weight 3.2 kg (7 lb), no module and one battery
Data Storage
Storage devices SDHC card, most standard USB storage devices, or fast Ethernet
Data file size 300 MB
I/O Ports
USB ports 3
Speaker out Yes
Video output Video out (SVGA)
Ethernet 10/100 Mbps
I/O Lines
Encoder 2-axis encoder line (quadrature, up, down, or clock/ direction)
Digital input 4 digital TTL inputs, 5 V
Digital output 4 digital TTL outputs, 5 V, 15 mA
Acquisition on/off switch Remote acquisition enabled TTL, 5 V
Power output line 5 V, 500 mA power output line (short-circuit protected)
Alarms 3 TTL, 5 V, 15 mA
Analog output 2 analog outputs (12 bits) ±5 V in 10 kΩ
Pace input 5 V TTL pace input
Display
Display size 26.4 cm (10.4 in.) (diagonal)
Resolution 800 pixels x 600 pixels
Brightness 700 cd/m2
Number of colors 16 million
Type TFT LCD
Power Supply
Battery type Smart Li-ion battery
Battery life Minimum 7 hours with two batteries
Environmental Specifications
Operating temperature range -10 °C to 45 °C (14 ºF to 113 ºF)
Storage temperature range –20 °C to 60 °C (–4 ºF to 140 ºF) with batteries
–20 °C to 70 °C (–4 ºF to 158 ºF) without batteries
Relative humidity Max. 70% RH at 45°C noncondensing
Ingress Protection Rating IP54
Shockproof rating Drop-tested according to MIL-STD-810G 516.6
Phased Array Module Specifications (Applies to OMNI-M-PA32128)
Voltage Low: 45 V
High: 90 V
Pulse width Adjustable from 30 ns to 500 ns; resolution of 2.5ns
Fall time <5 ns
Pulse shape Negative square pluse
Output impedance <30 ohms
Receiver
Gain range 0 dB to 74 dB in steps of 0.1 dB, maximum input signal 1.25 Vp-p
Input impedance 50 Ohms
System bandwidth 0.53 MHz to 21 MHz +10% (-3 dB)
Beam formation
Scan type Sectorial and linear
Aperture 32 elements
Number of elements 128 elements
Number of focal laws 256
Delay range transmission 0 us to 10 us in 2.5 ns increments
Delay range recetption 0 us to 10 us in 2.5 ns increments
Olympus OmniScan MX2 32:128 Ultrasonic
Acquisition Specifications
Frequency
Digitizing frequency 100 MHz (10 Bits)
A-scan (acquisition mode) Up to 6000 A-scans per second (512-point, 8-bit A-scan)
Maximum pulsing rate Up to 10 KHz (C-scan)
Depth in material 59.8 meter in steel (longitudinal wave), 10 ms in with compression
0.49 meter in steel (longitudinal wave), 81.9 us without compression
Display
Refresh rate A-scan: 60 Hz; s-scan: 20 Hz to 30 Hz
Envelope (echo-dynamic mode) Yes: Volume-corrected S-scan (30 Hz)
Synchronization
On internal clock 1 Hz to 10 kHz
External pace Yes
On encoder on 2 Axes: from 1 step to 65536 steps
Data Specifications
Number of data points Up to 8000
Real-time averaging 2, 4, 8, and 16
Rectification RF, full wave, half wave+, half wave-
Filtering Low-pass (adjusted to probe frequency), digital filtering (bandwidth, frequency range)
Video filtering Smoothing (adjusted to the probe frequency range)
Programmable TCG
Number of points 16: one TCG(time-corrected gain) curve per channel for focal laws
Storage
A-scan recording 6000 A-scans per second (512-point, 8-bit A-scan)
C-scan recording I, A, B, up to 10 kHz
Maximum file size Limited to available internal flash memory; OmniScan MX2: 300MB
Olympus OmniScan MX2 32:128 Ultrasonic
Included :
-Omniscan MX2 Mainframe
-32:128 Acquisition Module
-Heavy Duty Transport Case
-Manual and Documentation
-1 Lithium Ion Battery
-Charger and AC Cord
Reviews